How your own tools fared: fab analytics that show their working

The Analytics page in FabConnect: a period against the one before it, findings from fixed rules, link availability, equipment states, throughput, alarms, communication, same-model comparison and Verify across the fleet. Every number says how it was counted, and missing history is said, not filled in.

Anandakumar Thangaraju··8 min read

A fab that connects its tools to a host soon asks a second question: now that the data is arriving, how are the tools actually doing? Which ones lost their link most this month, which alarms keep coming back, which tool is slower than the others of its model, and is any of it better or worse than last month?

Those are questions about your own fleet, answered from your own records. This post goes through the Analytics page FabConnect added in version 0.3.0, what each part counts, and the rules it keeps so that a number on it can be argued with and checked.

A period, against the one before it

The page shows one period: the last 7, 30 or 90 days, or chosen first and last days (both included, up to 92 days, ending today at the latest). Every figure is set beside the same number of days just before it, so “alarms per tool-day” comes with the previous period’s figure and the change.

Days are local days in the site’s time zone, the one the shift handover settings use. The last day may still be running, and the page says “today so far” when it is.

The scope is the whole fab, one or more areas, one or more models, or chosen tools. Every section on the page reads the same period and scope.

The scorecard and its findings

At the top is a scorecard: link availability, unscheduled down time, alarms per tool-day, the median times to acknowledge and to clear an alarm, and the number of tools needing attention, each against the previous period.

Under it are the findings: plain sentences such as a tool’s link availability falling below 95 % and at least 5 points lower than in the previous period, an alarm set on at least half of the period’s days, or a tool replying far slower than the other tools of its model. They come from a short list of fixed rules with fixed thresholds, and the list is printed under the findings. They are not AI guesses: the same numbers always give the same sentences, in the same order. A rule fires only on numbers that are known, so a tool with no previous period to compare against is never called worse. Each finding links to the numbers behind it.

The Analytics page: the period and scope bar set to 30 days for the whole fab, the Fab scorecard with link availability, unscheduled down time, alarms per tool-day, the median times to acknowledge and to clear, and tools needing attention, a note saying where history starts, and the first findings, each an alarm flapping on a tool with a link to its numbers
The scorecard and the first findings for FabConnect’s simulated tools. Recording only began on 22 October, so the previous period shows as not known rather than as zero.

Every number opens its rule. Click a figure and a note says how it is counted, which records it is read from, and when it was computed. Every table downloads as CSV.

Availability, without counting maintenance as downtime

Availability on this page is link availability: the share of time the host link was selected, the line we explained in “Connected” isn’t “talking”. It says whether the host could talk to the tool, not whether the tool was processing, and the rule says so.

Alongside it are hours down, link drops, link MTBF (up hours over drops) and link MTTR (down hours over drops), and a heatmap of drops by hour and weekday. With no drop in the period, MTBF and MTTR are “not known”, not infinite.

Maintenance is never downtime. Time under a FabConnect maintenance window is left out of both up and down time. So is time before a tool’s history starts, or when no gateway was recording.

Equipment states

Tools that report their own Idle, Busy and Blocked states through EPT trackers get a breakdown of where the time went: productive, standby, engineering, scheduled down, unscheduled down (Blocked outside maintenance) and busy with no task given. The grouping is built from SEMI’s published E116 metadata files; not yet checked against the standard text.

Time FabConnect cannot place in a state is shown as not known: before a tool’s first readable EPT event, after one it could not read, and from a link drop to the tool’s next event (built from SEMI’s published E116 metadata files; not yet checked against the standard text). Tools that send no EPT events are named and left out of the totals, not counted as zero.

Alarms and communication

The alarms section counts alarms set, alarms per tool-day, alarms set during maintenance (counted, but never read as trouble), escalations sent and notices withheld by the alarm rules, and the median and 90th-percentile times to acknowledge and to clear. It marks chronic alarms (set on at least 5 days and on at least half the period’s days), flapping alarms (set at least 10 times, with at least half cleared within a minute), and an ALID that one tool sets far more often than the other tools of its model. Alarm IDs are kept per tool: ALID 1001 on one vendor’s tool is not ALID 1001 on another’s.

Communication health comes from the message log: messages a day, the median and 95th-percentile reply times the gateway measured, S9F9 transaction timeouts and link drops, with the tools that reply far slower than their model’s other tools marked.

Your tools against each other, and only each other

The comparison section puts the tools of each model side by side on availability, unscheduled down time, alarm rate and reply time, ranks them, and marks the ones that stand out. It needs at least two tools of a model in the scope.

The comparison is within your fleet: your tools against your other tools of the same model, on your gateway. FabConnect does not compare your fab with another company’s, and there is no cross-company benchmark behind any number on the page. The figures are worked out from the records in your own FabConnect database.

Verify across the fleet

The last section shows each tool’s latest completed full FabConnect Verify run, the pass rate by week and the checks failing on two or more tools. The results are read from each run’s stored report as they are. A Verify run is a self-check against FabConnect’s own test cases, not a SEMI compliance claim, and the section says so. What a GEM interface check catches explains what a run contains.

Throughput: counted once, never guessed

Throughput is completed units per tool, day and recipe, with cycle time (median and 90th percentile), the previous period like for like, and the other tools of the same model. What a unit is depends on the tool, so the source is set per tool on the GEM300 page’s Throughput section:

  • An E40 process job’s substrates, an E90 substrate, or, from version 0.4.0, one job-state event. The last is for a tool that reports every E40 process-job or E94 control-job state change on one event with a state value; you name which values mean started, complete and aborted (E40/E90/E94: built from SEMI’s published E40, E90 and E94 files; not yet checked against the standard text).
  • A tool’s own “unit complete” event, for a tool without GEM300.

Each completion is counted once. A report delivered twice counts once, and where the source maps the tool’s unit or job ID, a completion the tool sends again counts once too. Where it does not, the settings say that a re-sent report will count again, so map an ID where the tool reports one. With a job-state source, a job is paired and counted once by its ID, and an aborted or stopped job counts nothing.

Units are never guessed. A process job whose substrate count was not reported is counted as a job, not assumed to be some number of wafers. No state value is assumed either: a job-state event whose value is in none of your lists is not counted, and is listed on the tool’s Throughput settings so someone can see why.

OEE, off until tested

OEE is built: availability times performance times quality per tool and day, from the tool’s own equipment states (EPT: built from SEMI’s published E116 metadata files; not yet checked against the standard text) or link time, ideal cycle times set per tool and recipe, and a quality source. It is labelled “OEE: not yet tested on a tool”, and it stays off for a company until someone with settings:write turns it on. A factor without its inputs says “not configured” or “not known”; it is never guessed and never shown as 0 %.

The Fab health review

The page’s “Save as report” and “Schedule” buttons open the report builder on the Fab health review, with the page’s scope. It is the Analytics page as a report, in PDF, Excel or CSV, with throughput per tool and, only where OEE is turned on, OEE per tool. It can be scheduled like any other report and carry thresholds on availability, unscheduled down time, alarms per tool-day, the tools the findings name and completed units, so a week with nothing to say need not be sent. Reports operations actually read covers the schedules, history and formats.

History that says where it starts

The page can only count what FabConnect has recorded. When a period reaches back before a source’s history, the page says “History starts” with the date: the days before it are left out, not counted as zero, and the previous period is then not compared rather than compared against nothing. A previous period whose days are not all rolled up yet says so instead of passing off part of a period as the whole.

The honest boundary

Everything here is built, covered by the gateway’s and console’s tests, and has run against FabConnect’s simulated tools, including a simulator mode that runs production lots. It has not yet read a production fab’s history. OEE has not been tested on a tool, and stays off until you turn it on. To have FabConnect quoted for your own tools, ask for a quote by email.

Want this answered for your own tool set?

Start with a FabConnect Verify run (FC-VERIFY-RUN) of one of your tools: a GEM test run with a report that cites the frames, quoted by email. A fixed-fee readiness assessment of the fleet follows. You own both reports and can take them anywhere, including to another vendor.

Request a Quote