FabConnect Verify
Find out what a tool’s SECS/GEM interface really does
Verify connects to a tool as the host, runs a SEMI E37 / E5 / E30 test suite, and produces an evidence report in which every verdict points at the raw messages behind it. Run it on a laptop next to the tool, or from the FabConnect operator console.
Equipment makers
Your customers ask whether the GEM interface works before they sign off a tool. Verify lets your engineers run the same suite after every software release, on a Windows laptop next to the tool, and hand over a report with the evidence attached. Licensed annually.
Fabs, OSATs and solar lines
Before you integrate a tool, know what its SECS/GEM interface actually does. A Verify run at bring-up inventories the tool and finds the gaps while the vendor’s engineers are still on site; after a tool software update, re-run it from the operator console and see what changed.
What it checks
Each case passes on a correct implementation, and the cases that judge behaviour are shown to fail on a broken one: a simulated tool with a deliberate fault switched on, each fault caught by exactly its own cases.
| Area | What it checks |
|---|---|
| HSMS transport (E37) | Select, linktest, rejection of undefined message types and of data before select |
| Communication and control (E30) | Establish communication (S1F13), on-line and off-line requests, behaviour while off-line |
| Error handling (E5) | Unknown stream, unknown function, wrong device ID and malformed data each answered with the right S9 |
| Discovery | Status variables, data variables, collection events, equipment constants, alarms and process programs — inventoried before the other cases run |
| Status data and constants | Every advertised variable and constant reads back; unknown IDs refused; out-of-range writes refused and nothing stored |
| Event reports and alarms | Define, link and enable a report and read it back; enable and disable alarms; unknown IDs refused |
| Remote commands, clock, terminal | Unknown commands refused; clock read and set; terminal display accepted |
| Trace and process programs | Trace samples arrive in order; recipes list, read, upload, read back identically and delete |
| Spooling | Events spooled while the host is away are delivered on request; a purged spool delivers nothing; stream 1 refused |
| GEM300 (opt-in, on site) | E87 carrier actions, E40 and E94 job lifecycles, E90 substrate tracking. Jobs are created and removed again, never started |
| EPT trackers (--ept, passive) | Five experimental E116 EPT cases that only watch the state-change events the tool sends on its own for a window (60 s by default) and compare each reported Idle/Busy/Blocked transition with SEMI’s published E116-0707 state machines; no state-changing option, no carrier, nothing sent but the replies a host owes (built from SEMI’s published E116 metadata files; not yet checked against the standard text) |
In the operator console
For fabs running FabConnect: re-check a tool after a software update without carrying a laptop to it.
- Pick a connected tool and a stored profile; the page lists every check the run includes and which ones change equipment state, before anything is sent
- Follow the verdicts live, check by check, and cancel if you need to — the check in progress finishes and cleans up
- Compare with the tool’s previous run on the same profile: changed verdicts are highlighted, with the frames behind them
- While a run holds a tool, FabConnect releases its own session to it, refuses commands and a second run, and reconnects the tool however the run ends
- State-changing options need a separate permission and an explicit confirmation; every start, refusal and outcome is audited
- Works for every way FabConnect reaches a tool: HSMS where FabConnect dials the tool, HSMS where the tool dials in (Verify takes over the listening port and waits for the tool), and SECS-I serial through a local port or a device server — with the tool’s own line settings. Console runs on serial and passive tools have been tested against our simulated tool only, never against physical equipment
How it works on site
- Runs over HSMS (TCP/IP) or SECS-I (RS-232 serial)
- Windows and Linux; a single program with no installer and no runtime to add
- Read-only by default: no equipment constant written, no command run, no recipe changed. State-changing cases run only with an explicit flag, and are listed before anything is sent
- With a profile that names the tool’s idle state, every state-changing case is refused unless the tool reads idle
- Every case that changes the tool puts back what it can read back (spooling is left off, since E30 cannot read the earlier setting), and says so in the report if it could not
- An HTML report laid out in the order of E30’s own requirements — fundamental, then additional — plus a JSON report
- Every verdict cites the frames it rests on, and the whole report carries a SHA-256 fingerprint
- With a licence, reports are signed and anyone can check them; without one they are marked as an evaluation and left unsigned. A build that trusts FabConnect’s development root key, such as the demo, marks its reports “development build”
- Customer profiles: your fab’s or your customer’s GEM specification as extra test cases, without a new build
What we can and cannot claim
It is not a certification. No SEMI-run GEM certification programme exists, and Verify is a self-check against our own test cases. The report says what it is: verified against SEMI E37/E30 as implemented in FabConnect Verify.
It has been proven on software, not yet on a production tool. The cases pass on our simulated tool, the ones that judge behaviour fail on its broken variants, and the suite runs against an independent open-source GEM implementation we did not write. The first customer run is also the first hardware run, and we price that engagement accordingly.
A signature proves less than you might think. It shows which licensed copy produced a report and that the report has not changed since. It cannot prove the run happened as described, because the signing key sits with the licensee. A build that trusts FabConnect’s development root key, such as the demo, marks its reports “development build”.
Pricing is by email
Your first quote is for a FabConnect Verify run (FC-VERIFY-RUN) of one tool, for an equipment maker or a fab. A readiness assessment of a fab's fleet follows it; equipment makers can then take an annual licence. Tell us about the tool and we will reply with a quote.
sales@fabconnect.io