FabConnect Verify

Running the SECS/GEM self-check from the console or the command line.

FabConnect Verify connects to a tool as its host, runs a SEMI E37 / E5 / E30 test suite (and, opted in, GEM300 cases), and writes a report in which every verdict cites the frames it rests on. It is a self-check against our own test cases, not a SEMI certification.

In the operator console

The Verification page runs a stored profile against a connected tool:

  1. Pick the tool and a profile; the page lists every case the run includes and which ones change equipment state
  2. Start, and follow the verdicts live; cancel if you need to (the case in progress finishes and cleans up)
  3. Open the frames behind any verdict, download the JSON report and the HTML statement, and see which verdicts changed since the tool’s previous run with the same profile and options

While a run holds a tool, FabConnect releases its own session to it: commands to the tool are refused (409), live data pauses, and a second run is refused. The tool is reconnected when the run ends, however it ends.

Every kind of tool FabConnect connects to can be run from the console:

  • HSMS, FabConnect dialling the tool: Verify dials the same address.
  • HSMS, the tool dialling in (passive mode): FabConnect stops listening, Verify listens on the same port and waits for the tool to dial in for each session the suite needs, then FabConnect listens again. If the tool never dials in, the run fails with that reason after a bounded wait, and FabConnect still listens again. A read-only run needs about five dial-ins (one more with the state-changing spooling check), each coming after the tool’s own reconnect delay (T5), so allow for that.
  • SECS-I serial: FabConnect lets go of the port (or the device server’s connection), Verify opens the same line with the tool’s baud rate, device ID, E4 timers and master setting, and FabConnect reopens it and re-establishes communication afterwards. The HSMS-only cases report not tested, as on the command line.

How long a run waits for a passive tool to dial in is the protocol engine’s --verify-dial-in setting (FABCONNECT_VERIFY_DIAL_IN_SECONDS), 60 seconds by default.

The run summary shows how the tool was reached. Console runs on serial and passive tools have been tested against our simulated tool only, never against physical equipment.

A read-only run needs messages:send. State-changing options also need settings:write and an explicit confirmation of the cases they will run. Every start, refusal and outcome is audited. While a spool transfer to FabConnect is running, no run starts. While the tool holds spooled data FabConnect has not collected (its SpoolCountActual above 0), a SECS-I tool is not run at all, since it cannot tell the run from FabConnect and would hand the run its spool, and an HSMS tool is not run with the state-changing options, whose spooling checks would change its spool. Those checks are also skipped on a tool that holds spooled data or whose count cannot be read; on a tool that does not report SpoolCountActual at all, they purge its spool to start from empty.

On the command line

bash
fabconnect-verify 192.168.1.100:5000 --device-id 1
fabconnect-verify serial:COM3 --baud 9600
fabconnect-verify serial:tcp://10.0.0.5:4001          # device server, raw TCP (line set on the server)
fabconnect-verify serial:rfc2217://10.0.0.5:4001 --baud 9600
fabconnect-verify serial:COM3 --baud 9600 --t1 0.5 --t2 10 --t4 45 --retries 3 --master   # the tool’s own E4 line settings
fabconnect-verify listen:5000 --dial-in 60                # the tool dials in (HSMS active mode)
fabconnect-verify 192.168.1.100:5000 --profile fab-spec.yaml --allow-mutating
fabconnect-verify --check-report report.json

A single program for Windows and Linux. Read-only by default; --allow-mutating, --gem300 and --probe-remote-commands opt in to cases that change the tool. --ept runs only the passive E116 EPT cases, which change nothing and need neither --allow-mutating nor a carrier (built from SEMI’s published E116 metadata files; not yet checked against the standard text).

Reports and licences

With a licence, reports are signed and --check-report verifies them. Without one, or for a feature the licence does not cover, reports are marked as an evaluation and are not signed. A build that trusts FabConnect’s development root key, such as the demo, marks its reports “development build”.