Equipment Dictionaries (SEDD)
Importing a tool supplier’s SEMI E172 SEDD and comparing it with the tool: built from SEMI’s published E172 schema files; not yet checked against the standard text.
A SEDD (SECS Equipment Data Dictionary, SEMI E172) is the XML file in which a tool’s supplier lists its status variables, data variables, equipment constants, collection events, alarms, value formats and remote commands. Built from SEMI’s published E172 schema files; not yet checked against the standard text.
What works
- Import (console: Equipment dictionaries) a SEDD of schema revision 0320, 1023 or 0225. It is validated against FabConnect’s own model of SEMI’s schemas, which our tests check gives the same verdict as SEMI’s schema files on SEMI’s examples and thousands of altered copies of them. A document no revision accepts is refused with its schema errors and their lines.
- Bind it to tools, and compare it with what a tool reports now, through read-only GEM requests: what only one side lists, and where names, units, formats, constant limits and alarm texts differ (built from SEMI’s published E172 schema files; not yet checked against the standard text).
- Generate a FabConnect Verify profile from it, so a Verify run judges the tool against what the supplier’s file lists, with the frames each verdict rests on. Remote commands are listed but never sent.
- The supplier’s own statements about standards are shown as written, marked as the supplier’s; FabConnect has not checked them and does not repeat them.
Interface A
A bound SEDD (built from SEMI’s published E172 schema files; not yet checked against the standard text) can fill in descriptions, units and types in the Interface A self-description, never adding items or changing identifiers. Interface A is built from SEMI’s published proto and schema files, not yet checked against the standard text; not tested against third-party Interface A clients.
Not supported
- The 0115 and 1015 revisions are refused (recognised, with that reason). Writing a SEDD from a tool’s discovery is not offered.
- GEM has no standard way to list remote commands, so the comparison does not check them.
- Documents up to 16 MiB, UTF-8, with no DOCTYPE; built from SEMI’s published E172 schema files; not yet checked against the standard text.
Endpoints
POST,GET /api/v1/sedd;GET,DELETE /api/v1/sedd/{docId};GET /api/v1/sedd/{docId}/xmland/profile.yaml;POST /api/v1/sedd/{docId}/verify-profileGET,PUT,DELETE /api/v1/equipment/{id}/sedd;POST /api/v1/equipment/{id}/sedd/compare