HSMS Configuration

SEMI E37 connections: modes, timers and session control.

Modes

Set mode on the equipment record: active (FabConnect connects to the tool’s address and port) or passive (FabConnect listens on that port for the tool). See Equipment Endpoints.

Timers

TimerDefaultRangeEquipment fieldMeaning
T345 s1–120 shsms.t3_reply_sReply timeout
T510 s1–240 shsms.t5_connect_separation_sConnect separation: wait before reconnecting
T65 s1–240 shsms.t6_control_sControl transaction timeout
T710 s1–240 shsms.t7_not_selected_sNot-selected timeout
T85 s1–120 shsms.t8_intercharacter_sInter-character timeout: longest gap between the bytes of one message
Linktest30 s1–600 shsms.linktest_interval_sInterval between linktests on a selected link

Each timer can be set per tool, in whole seconds, in the equipment form or on the equipment record (hsms in Equipment Endpoints). A timer left unset uses the default. New values take effect on the next connect.

Session control

  • Select.req / rsp start the session
  • Linktest.req / rsp check the link is alive; a linktest not answered within T6 drops it
  • Separate.req ends it

A link also drops when the tool refuses Select, leaves a control message (Select, Linktest) unanswered for T6, or stops part-way through a message for longer than T8; the reason says which.

When a link drops, the engine reconnects after T5, backing off up to a minute. Disconnecting a tool through the API ends the connection without reconnecting.

Notes

  • One host at a time: most tools accept a single selected HSMS host, so FabConnect cannot share a tool with another host
  • Use a separate port per tool in passive mode