HSMS Configuration
SEMI E37 connections: modes, timers and session control.
Modes
Set mode on the equipment record: active (FabConnect connects to the tool’s address and port) or passive (FabConnect listens on that port for the tool). See Equipment Endpoints.
Timers
| Timer | Default | Range | Equipment field | Meaning |
|---|---|---|---|---|
| T3 | 45 s | 1–120 s | hsms.t3_reply_s | Reply timeout |
| T5 | 10 s | 1–240 s | hsms.t5_connect_separation_s | Connect separation: wait before reconnecting |
| T6 | 5 s | 1–240 s | hsms.t6_control_s | Control transaction timeout |
| T7 | 10 s | 1–240 s | hsms.t7_not_selected_s | Not-selected timeout |
| T8 | 5 s | 1–120 s | hsms.t8_intercharacter_s | Inter-character timeout: longest gap between the bytes of one message |
| Linktest | 30 s | 1–600 s | hsms.linktest_interval_s | Interval between linktests on a selected link |
Each timer can be set per tool, in whole seconds, in the equipment form or on the equipment record (hsms in Equipment Endpoints). A timer left unset uses the default. New values take effect on the next connect.
Session control
- Select.req / rsp start the session
- Linktest.req / rsp check the link is alive; a linktest not answered within T6 drops it
- Separate.req ends it
A link also drops when the tool refuses Select, leaves a control message (Select, Linktest) unanswered for T6, or stops part-way through a message for longer than T8; the reason says which.
When a link drops, the engine reconnects after T5, backing off up to a minute. Disconnecting a tool through the API ends the connection without reconnecting.
Notes
- One host at a time: most tools accept a single selected HSMS host, so FabConnect cannot share a tool with another host
- Use a separate port per tool in passive mode